( ESNUG 389 Item 2 ) --------------------------------------------- [03/06/02]

From: Ofer Paperni <ofer.paperni@motorola.com>
Subject: PhysOpt def2pdef Chokes Trying To Convert Already Routed DEF 5.3

Hi John,

I have this problem while trying to convert the routed DEF (from SE-Ultra,
after CTgen and Wroute) to PDEF with the def2pdef I get the following:

   Warning: Detect syntax error near token '*' at line 415183. Continue to
     parse until the next correct rule can be applied. (DEFIN-16)
   Warning: Probably the special wiring continue point has incorrect syntax.
     (DEFIN-20)

Those lines in the DEF are net routing information:

  - weim_lba_b ( PIN weim_lba_b ) ( z497 x )
  + ROUTED m1 ( 4329800 574150  ) via1 ( * * 500 )  ( 4351200 *  500  ) via2
  ( * * 550 )  ( * 576650  550  ) via3 ( * * 550 )  ( 4352600 *  ) ;

Any ideas anyone?  The .DEF version is 5.3

    - Ofer Paperni
      Motorola Semiconductor                     Israel