( ESNUG 360 Item 3 ) --------------------------------------------- [11/02/00]

From: lye@mhcnet.micro.lucent.com (Lun Ye)
Subject: Questions On PhysOpt Signal Integrity & Primetime Crosstalk News

Hi John,

I have the following two Primetime questions:

(1) In your Boston SNUG Trip Report, you mentioned that Aart de Geus gave
    the keynote address. two of the interesting tidbits are of special
    interest to me:

      a. PrimeTime is now in beta with crosstalk analysis capability
      b. plans to integrate signal integrity capability into PhysOpt

    Do you have more information on this?  Where can I learn more, in
    addition to from Synopsys source?

(2) How can I speed up these commands (in any order)?

    report_timing -nosplit -nets -through net_abc -delay_type min_rise
    report_timing -nosplit -nets -through net_abc -delay_type min_fall
    report_timing -nosplit -nets -through net_abc -delay_type max_rise
    report_timing -nosplit -nets -through net_abc -delay_type max_fall

Many thanks in advance,

    - Lun Ye
      Lucent Technologies, Inc                   Allentown, PA