( ESNUG 250 Item 3 ) -------------------------------------------- [9/6/96]

From: Andrew Frazer <Andy.Frazer@idt.com>
Subject: I Need Better Control Of Synopsys SDF File Generation

Hey, John, I have a question about SDF files.
 
We are trying to use Synopsys for our pre-layout delay calculator.  We use
Synopsys to write out the SDF file, then we back-annotate the SDF file into
Verilog and/or Ikos.
 
The problem is that Synopsys writes out an SDF file where all three timing
parameters (min/typ/max) are identical because it calculates the delays
based on the last "set_operating_conditons" command.
 
We want to write out one SDF file where "min" delays are calculated
with "best_case_commercial" operating conditions, "typ" delays are
calculated with "typical_case" operating conditions, and "max" delays
are calculated with "worst_case_conditions".
 
The current workaround is to write out three different SDF files, each of
which is calculated with under different operating_conditions.  Any ideas?

  - Andy Frazer
    Integrated Device Technology 



 Sign up for the DeepChip newsletter.
Email
 Read what EDA tool users really think.


Feedback About Wiretaps ESNUGs SIGN UP! Downloads Trip Reports Advertise

"Relax. This is a discussion. Anything said here is just one engineer's opinion. Email in your dissenting letter and it'll be published, too."